capsule endoscopy to detect normally positioned duodenal papilla: performance comparison of sb and sb2
Clicks: 276
ID: 184608
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
73.3
/100
276 views
227 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #27 of 188 articles by views in colloids and surfaces a: physicochemical and engineering aspects
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 188 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Purpose. PillCam SB2 capsule endoscopy, an upgraded version of widely used SB capsule endoscopy, was examined for its performance by comparing with SB. Methods. Examinees with various indications were enrolled for SB2 capsule endoscopy; subjects were also enlisted for the old SB capsule endoscopy. Number of photo images containing papilla of Vater was counted. Shape of the papilla seen in each image was evaluated by scoring 3 (fully observable papilla), 2 (more than half outline), or 1 (less than half outline) points. Images obtained from SB and SB2 were also subjectively compared; resolution and brightness were scored by six experienced endoscopists. Results. Baseline characteristics of two study groups (n=30 each) were not significantly different. Number of images of the papilla revealed to show similar results between SB (3.1±1.1, range 1~5) and SB2 (3.1±1.5, range 1~8) (P=0.62). The maximum points of outline of papilla evaluated from each subject were also similar between two groups. New SB2 revealed to be superior to SB in terms of resolution but not significantly different in brightness. Conclusion. Our study showed that superiority of SB2 over SB is rather marginal on examining duodenal papilla.
| Reference Key |
park2012gastroenterologycapsule
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Sanghoon Park;Hoon Jai Chun;Bora Keum;Yeon Seok Seo;Yong Sik Kim;Yoon Tae Jeen;Hong Sik Lee;Soon Ho Um;Chang Duck Kim;Ho Sang Ryu |
| Journal | colloids and surfaces a: physicochemical and engineering aspects |
| Year | 2012 |
| DOI |
10.1155/2012/202935
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.