Gas chromatography and liquid chromatography coupled to mass spectrometry for the determination of fluorotelomer olefins, fluorotelomer alcohols, perfluoroalkyl sulfonamides and sulfonamido-ethanols in water.
Clicks: 379
ID: 18324
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
73.0
/100
379 views
263 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #9 of 58 articles by views in journal of chromatography a
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this work, the suitability of gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the multi-class determination of different families of neutral per- and polyfluoroalkyl substances (PFASs), such as fluorotelomer olefins (FTOs), alcohols (FTOHs) and fluorooctanesulfonamides (FOSAs) and sulfonamido-ethanols (FOSEs), was investigated and compared. Regarding GC-MS, the use of a semi-polar GC column (DB-624, 6%-cyanopropilphenyl 94%-dimethyl polysiloxane) allowed the adequate separation of all the compounds while chemical ionisation (CI) of positive ions as ionisation technique provided the best responses. Concerning UHPLC-MS/MS, atmospheric pressure chemical ionisation (APCI) and photoionisation (APPI) sources allowed the ionisation of all studied neutral PFASs, including FTOs for the first time. High vaporizer temperatures (450 °C) and acetonitrile/water mobile phase mixtures were required to favour the ionisation of FTOs, with adequate ionisation for FTOHs, FOSAs and FOSEs. The chromatographic separation, performed on a totally porous column (Luna C18), allowed the successful separation of the four families of neutral PFASs. After comparing the performance of the studied methods, the highest detectability was achieved using UHPLC-APCI-MS/MS and it was chosen in combination with a solid-phase extraction (SPE) procedure for the analysis of neutral PFASs in water samples. The whole method provided low limits of detection (0.003-6 µg L), good precision (RSD < 9%) and trueness (relative error < 10%). The methodology was applied to the analysis of river water samples and the presence of some neutral PFASs were detected (8:2 FTO) and quantified (4:2 FTOH and N-EtFOSA) at low concentration levels (ng L).
| Reference Key |
ayalacabrera2019gasjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Ayala-Cabrera, J F;Moyano, E;Santos, F J; |
| Journal | journal of chromatography a |
| Year | 2019 |
| DOI |
S0021-9673(19)30850-7
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.