a flow injection system for the spectrophotometric determination of lead after preconcentration by solid phase extraction onto amberlite xad-4
Clicks: 170
ID: 182495
2008
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
170 views
11 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #11 of 18 articles by views in international journal of advanced computer science and applications
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
An on-line flow injection analysis (FIA) system for determination of lead (II) in water samples with a preconcentration step and spectrophotometric detection was investigated. The system is based on preconcentration of lead (II) on a column packed with Amberlite XAD-4 resin and detection by means of 4-(2-pyridylazo)resorcinol (PAR)–lead complex formation with maximum absorption at 523 nm. Chemical and FIA variables influencing performance of the system were optimised. Two linear calibration curves with a range of 0.01 - 0.40 and 0.40 – 0.80 mg L-1 were obtained. The developed system allowed a throughput rate of 16 samples h-1 with a 9-fold enrichment factor and a detection limit of 7 µg L-1. Relative standard deviation for 10 replicated injections of 0.25 mg L-1 was 2.3%. Recoveries of the method were in the range of 80-94 %. The procedure was validated by analysis of lead (II) in real water samples, and the results were statistically compared with those obtained by flame atomic absorption spectrophotometry (FAAS). The results obtained both by the proposed method and by FAAS were in good agreement.
| Reference Key |
klamtet2008maejoa
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Jintana Klamtet |
| Journal | international journal of advanced computer science and applications |
| Year | 2008 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.