inter-rater reliability of modified alberta stroke program early computerized tomography score in patients with brain infarction

Clicks: 593
ID: 182195
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #6 of 133 articles by views in 2017 ieee international conference on communication, networks and satellite, comnetsat 2017 - proceedings

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 133 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: The Alberta Stroke Program Early Computerized Tomography Score (ASPECTS) was used to detect significant early ischemic changes on brain CT of acute stroke patients. We designed the modified ASPECTS and compared it to the above system based on the inter-rater reliability. Methods: A cross-sectional validation study was conducted based on the inter-rater reliability. The CT images were chosen from the stroke data bank of Ghaem hospital, Mashhad in 2010. The inclusion criteria were the presence of middle cerebral artery territory infarction and performance of CT within 6 hours after stroke onset. Axial CT scans were performed on a third-generation CT scanner (Siemens, ARTX, Germany). Section thickness above posterior fossa was 10 mm (130 kV, 150 mAs). Films were made at window level of 35 HU. The brain CTs were scored by four independent radiologists based on the ASPECTS and modified ASPECTS. The readers were blind to clinical information except symptom side. Cochrane Q and Kappa tests served for statistical analysis. Results: 24 CT scans were available and of sufficient quality. Difference in distribution of dichotomized ≤7 and >7 ASPECT scores between four raters was significant (Q=13.071, df=3, p=0.04). Distribution of dichotomized <6 and ≥6 scores based on modified ASPECT system between 4 raters was not significantly different (Q=6.349, df=3, p=0.096). Conclusions: Modified ASPECT method is more reliable than ASPECTS in detecting major early ischemic changes in stroke patients candidated to tPA thrombolysis.
Reference Key
ghandehari2011journalinter-rater Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Kavian Ghandehari;Mohammad Reza Rezvani;Mohammad Taghi Shakeri;Mahdi Mohammadifard;Alireza Ehsanbakhsh;Mahyar Mohammadifard;Alireza Mirgholami;Reza Boostani;Kosar Ghandehari;Zahra Izadi-Mood
Journal 2017 ieee international conference on communication, networks and satellite, comnetsat 2017 - proceedings
Year 2011
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.