Determination of pesticides of different chemical classes in drinking water of the state of Santa Catarina (Brazil) using solid-phase microextraction coupled to chromatographic determinations.
Clicks: 349
ID: 181762
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
349 views
49 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #97 of 403 articles by views in Environmental science and pollution research international
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 403 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The evaluation of the concentration of pesticides in drinking water presents a real concern. In this study, a simple and rapid method based on solid-phase microextraction (SPME) followed by gas chromatography-mass spectrometry and electron capture detectors was developed aiming at multiclass determination of 23 pesticides regulated by the Brazilian legislation. The extraction was carried out by direct immersion mode (DI-SPME) using DVB/Car/PDMS fiber coating. In order to improve the extraction efficiency, parameters such as temperature, salting-out effect, and extraction time were optimized. The method was evaluated using drinking water samples spiked with the analytes at different concentrations, and it showed good linearity in the range studied. The values obtained for limits of quantification (LOQ) were below the limits established by Brazilian regulations. Accuracy and precision of the method exhibited satisfactory results, providing relative recoveries from 70 to 123.34% at three spiked levels, and the relative standard deviations ranged from 0.53 to 24.8%. The method was applied in 20 drinking water samples from 13 cities in the State of Santa Catarina, Brazil.
| Reference Key |
do-carmo2020determinationenvironmental
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | do Carmo, Sângela Nascimento;Mendes, Leila Dorácio;Corazza, Gabriela;Comelli, Heloísa;Merib, Josias;Carasek, Eduardo; |
| Journal | Environmental science and pollution research international |
| Year | 2020 |
| DOI |
10.1007/s11356-020-10287-0
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.