Development of a simple method to quantify fipronil and its intermediates in soil.
Clicks: 406
ID: 181754
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
81.5
/100
406 views
275 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #2 of 5 articles by views in Analytical methods : advancing methods and applications
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A simple and reproducible method was developed and validated for simultaneous quantification of the pesticide fipronil and its intermediates fipronil desulfinyl, fipronil sulfone and fipronil sulfide, in soil. The analytes were extracted by ultrasonic bath and the ratio of solvents (hexane/acetone), number and time of cycles were optimized by Box-Behnken design with a triplicate central point. The optimal extraction conditions were achieved through a response surface analysis. The clean-up step was conducted by cartridges of solid phase extraction (SPE) containing silica (Florisil®) and aluminum oxide. Gas chromatography with electron capture detection (GC-ECD) was employed for separating fipronil and its intermediates with a suitable resolution and runtime of 20 minutes. The best quantification was achieved with 1 : 1 (v/v) acetone/hexane and 2 ultrasound cycles of 15 minutes each. The recovery values were between 81 to 108%, with relative standard deviation (RSD) lower than 6%, with no effect of the used matrix. Analytical curves presented regression coefficients values above 0.9908 for a concentration range from 0.005 to 0.6 μg g-1. Limits of detection (LOD) from 0.002 to 0.006 μg g-1 and limits of quantification (LOQ) from 0.006 to 0.020 μg g-1 were reached for all analytes. This method can be used to monitor and quantify fipronil and its intermediates in soil.
| Reference Key |
tomazini2020developmentanalytical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Tomazini, Rafaella;Grosseli, Guilherme Martins;Nara Ribeiro de Sousa, Diana;Fadini, Pedro Sergio;Talarico Saia, Flávia;Langenhoff, Alette;van der Zaan, Bas;Mozeto, Antonio Aparecido; |
| Journal | Analytical methods : advancing methods and applications |
| Year | 2020 |
| DOI |
10.1039/d0ay00924e
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.