Occurrence and Determination of Haloacetic Acids in Metro Manila Drinking Water
Clicks: 292
ID: 181743
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
292 views
52 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #3 of 5 articles by views in science diliman
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Haloacetic acids are found in chlorinated water with high organic matter content. An analytical method based on a US EPA method for measuring these compounds in water is described. The optimized method used diethyl ether as extraction solvent with sulphuric acid-methanol as esterification agent and subsequent detection by gas chromatography-electron capture detection. Evaluation of this method showed that it was linear in the concentration range of 10 to 150 µg L-1 and the method detection limits were from 17 to 57 µg L-1. Although the method demonstrated low recoveries (16 to 43%), it is useful in the quantitative determination of monochloroacetic acid as well as the qualitative determination of other haloacetic acids in water. Drinking water samples taken from different areas in Metro Manila serviced by the local treatment plants were analysed using the method. Monochloroacetic acid, monobromoacetic acid, and bromochloroacetic acid were detected in these samples. Monochloroacetic acid was quantified and found in concentrations ranging from 19 to 157 µg L-1. In most of the water samples, the concentration of monochloroacetic acid exceeded the US EPA maximum allowable total concentration of 60 µg L-1 for the five haloacetic acids (monochloro-, dichloro-, trichloro-, monobromo-, and dibromoacetic acids) in drinking water. This initial study established the occurrence of potentially harmful haloacetic acids in the local drinking water supplies.
| Reference Key |
rodriguez2009occurrencescience
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Rodriguez, Irene B.;Espino, Maria Pythias B.; |
| Journal | science diliman |
| Year | 2009 |
| DOI |
DOI not found
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.