pengaruh pemilihan gigi penyangga terhadap desain cengkeram rangka logam effect of abutment selection to the clasp design of metal frame

Clicks: 10
ID: 180322
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #100 of 103 articles by views in The Journal of organic chemistry

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Advantages of metal framework partial denture than conventional denture base include power and can be made as thin as possible. But the success is influenced by clasp design. Many things to be considered in positioning the clasp, therefore knowledge of the diagnosis, indications, contraindications, and biomechanical properties of the metal that used to be important in the treatment. This study aimed to determine the retentive strength of akers and back action for the abutment first molar and first premolar and the upper and lower clasp design is most appropriate for the abutment. Research using 8 samples I (gypsum base with natural teeth) and 8 samples II (gypsum base metal crown) maxillary and mandibulary first premolar and first molar with a depth of 0.25 mm undercut. Sample II soaked in artificial saliva, surveyed and was prepared for a rest seat. Akers and back action clasp were inserted on a metal crown and measured their retentive strength with Instron UTM. The results obtained indicate the highest retentive strength metal abutment crown molar and premolar with Akers compared to back action. Highest retentive strength on metal molar abutment crowns with the Akers and upper premolars with metal crowns back action. There are significant differences between the groups retentive strenth of clasp design. It was concluded that best retentive force on the upper molars with akers and upper premolars with Akers.
Reference Key
dharmautama2012journalpengaruh Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Moh. Dharmautama;Edy Machmud;Asmah Fahmi Rasyid
Journal The Journal of organic chemistry
Year 2012
DOI
10.15562/jdmfs.v11i2.301
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.