heavy silicone oil as a long-term endotamponade agent for complicated retinal detachments

Clicks: 186
ID: 180195
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #525 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
We retrospectively evaluated a heavy silicone oil (HSO) as a long-term intraocular endotamponade agent to treat complicated RD by inferior PVR in 25 eyes of 25 patients. Patients underwent PPV and injection of Oxane HD as an internal tamponade agent. A comparison of preoperative and postoperative BCVA at month 1, month 6, and last visit was made in the group in which HSO was removed and in the group in which HSO was not removed. Statistical calculations were performed using the Wilcoxon test. The HSO was removed from 11 patients after a mean of 26.55 ± 21.38 months. The HSO remained inside the vitreous cavity in 14 eyes due to a high chance of PVR recurrence (mean follow-up period, 11.07 ± 7.44 months). Anatomic success was achieved in 92%. The BCVA in the group, in which HSO was not removed, improved significantly during the first 6 months. Among the patients who had the oil removed, there was improvement in BCVA after 1 month. Oil emulsification was the most common adverse effect in 52% of eyes. HSO is an effective tamponade in complex rhegmatogenous and tractional RD complicated by PVR. HSO can remain in the eye for long periods with relative tolerability and safety.
Reference Key
prazeres2014biomedheavy Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Juliana Prazeres;Octaviano Magalhães;Luiz F. A. Lucatto;Rodrigo Milan Navarro;Nilva S. Moraes;Michel E. Farah;André Maia;Maurício Maia
Journal spectrochimica acta - part a: molecular and biomolecular spectroscopy
Year 2014
DOI
10.1155/2014/136031
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.