Introducing an affordable catalyst for biohydrogen production in microbial electrolysis cells.

Clicks: 299
ID: 17972
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #4 of 36 articles by views in journal of bioscience and bioengineering

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This study reports the fabrication of a new cathode electrode assembly using polyaniline (PANI) and graphene on a stainless steel mesh (SSM) as an alternative for the conventional expensive cathode of microbial electrolysis cells (MECs). With respect to the previous efforts to propose an efficient and cost-effective alternative for platinum (Pt) catalysts and cathode electrodes, the present study investigates the assessment of different catalysts to elucidate the potential of the modified SSM cathode electrode for larger-scale MECs. In the case of feeding dairy wastewater to the MEC, the maximum hydrogen production rate and COD removal were obtained by SSM/PANI/graphene cathode and had the values 0.805 m H m anolyte day and 82%, respectively, at the applied potential of 1 V. These values were only 20% and 7% lower than those of the MEC with Pt on the carbon cloth cathode, respectively. The coulombic efficiencies of SSM/Pt and SSM/PANI/graphene were seen to be 64.48% and 56.67%, respectively. It was also concluded that the fabrication cost of the modified cathode was 50% lower than the conventional cathodes with Pt on the carbon cloth. Finally, the evaluation of the modified cathode performance was achieved based on Fourier transform infrared spectroscopy, linear sweep voltammetry, scanning electron microscopy, and atomic force microscopy.
Reference Key
ghasemi2019introducingjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ghasemi, Behzad;Yaghmaei, Soheila;Abdi, Kaveh;Mardanpour, Mohammad Mahdi;Haddadi, Seyyed Arash;
Journal journal of bioscience and bioengineering
Year 2019
DOI
S1389-1723(18)31138-1
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.