endoscopic ultrasound-guided biliary drainage using self-expandable metal stent for malignant biliary obstruction

Clicks: 255
ID: 178595
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #32 of 188 articles by views in colloids and surfaces a: physicochemical and engineering aspects

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 188 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Purpose. Endoscopic ultrasound-guided biliary drainage (EUS-BD) has been increasingly reported worldwide. However, studies concerning EUS-BD from Mainland China are sporadic. This study aims to investigate the feasibility, efficacy, and safety of EUS-BD using SEMS in a single center from Mainland China. Methods. Between November 2011 and August 2015, 24 patients underwent EUS-BD using a standardized algorithm. Results. Three patients underwent rendezvous technique (RV), 4 underwent hepaticogastrostomy (HGS), and 17 underwent choledochoduodenostomy (CDS). The technical and clinical success rates were 95.8% (23/24) and 100% (23/23), respectively. Mean procedure time for the CDS group (35.9 ± 5.0 min) or HGS group (39.3 ± 5.0 min) was significantly shorter than that for the RV group (64.7 ± 9.1 min) (P<0.05). Complications (13%) included (1) cholangitis and (2) postprocedure hemorrhage. During the follow-up periods (mean 6.4 months), 22 (91.7%) patients died of tumor progression with mean stent patency of 5.8 ± 2.2 months. Stent occlusion occurred in 2 (8.7%) patients. Conclusion. EUS-BD using SEMS is a feasible, effective, and safe alternative for biliary decompression after failed ERCP. EUS-RV may not be the first-line choice for EUS-BD in a medium volume center. Further evaluation and experience of this method are needed.
Reference Key
lu2017gastroenterologyendoscopic Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Lei Lu;Xiaowei Tang;Hangbin Jin;Jianfeng Yang;Xiaofeng Zhang
Journal colloids and surfaces a: physicochemical and engineering aspects
Year 2017
DOI
10.1155/2017/6284094
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.