analysis of transient voltage stability in a low voltage distribution network using sst for the integration of distributed generations

Clicks: 249
ID: 178265
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #21 of 85 articles by views in Molecular diversity

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Models of a low voltage distribution network using a typical tertiary-structure solid state transformer (SST) for the integration of distributed generations (DGs) and a conventional low voltage distribution network integrated with DGs were established to study the transient voltage stability issue, using the power system simulation software PSCAD. Effects on the transient voltage stability of the load bus and DC bus in the SST system are analyzed when grid-side cable line faults (such as short circuit and line disconnection) occur or the total output of DGs drops greatly. The results show that, comparing with the conventional system, the SST has apparent advantages on enhancing the transient voltage stability of load bus while facing different disturbances, even though SST has to regulate the voltage passively. Short circuit faults at different location of the grid-side line have different effects on the transient voltage stability, while the effect of disconnection fault is not related to fault location. Moreover, the DC bus voltage is easy to keep climbing continually when short circuit fault of the line occurs that is close to the SST input stage or disconnection fault occurs at any location of the line. If a battery energy storage station is installed, the transient voltage stability of DC bus and load bus will be improved effectively because of the regulation function of battery storage.
Reference Key
li2018journalanalysis Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Sheng Li;Zhihao Zhou;Qiqi Shan;Jiani An
Journal Molecular diversity
Year 2018
DOI
10.1155/2018/3498491
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.