mixed ion-exchanger chemically modified carbon paste ion-selective electrodes for determination of triprolidine hydrochloride
Clicks: 127
ID: 178086
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
30.0
/100
127 views
13 readers
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #71 of 77 articles by views in reading & writing
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Triprolidine hydrochloride (TpCl) ion-selective carbon paste electrodes were constructed using Tp-TPB/Tp-CoN and Tp-TPB/Tp-PTA as ion-exchangers. The two electrodes revealed Nernstian responses with slopes of 58.4 and 58.1 mV decade−1 at 25 °C in the ranges 6 × 10−6–1 × 10−2 and 2 × 10−5–1 × 10−2 M for Tp-TPB/Tp-CoN and Tp-TPB/Tp-PTA, respectively. The potentials of these electrodes were independent of pH in the ranges of 2.5–7.0 and 4.5–7.0, and detection limits were 6 × 10−6 and 1 × 10−5 M for Tp-TPB/Tp-CoN and Tp-TPB/Tp-PTA, respectively. The electrodes showed a very good selectivity for TpCl with respect to a large number of inorganic cations and compounds. The standard addition, potentiometric titration methods and FIA were applied to the determination of TpCl in pure solutions and pharmaceutical preparations. The results obtained were in close agreement with those found by the official method. The mean recovery values were 100.91% and 97.92% with low coefficient of variation values of 0.94%, and 0.56% in pure solutions, 99.82% and 98.53% with coefficient of variation values of 2.20%, and 0.73% for Actifed tablet and Actifed syrup, respectively, using the Tp-TPB/Tp-CoN electrode, and 98.85%, and 99.18% with coefficient of variation values of 0.48% and 0.85% for Actifed tablet and Actifed syrup, respectively, using the Tp-TPB/Tp-PTA electrode.
| Reference Key |
issa2010journalmixed
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Yousry M. Issa;Fekria M. Abu Attia;Nahla S. Ismail |
| Journal | reading & writing |
| Year | 2010 |
| DOI |
10.1016/j.jare.2010.02.006
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.