a new method of estimating intracranial elastance

Clicks: 88
ID: 178076
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #44 of 45 articles by views in advances in materials science and engineering

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Objective: Current methods of calculating Intracranial Elastance Index (IEI) depend from CSF pulse-wave, whose shape may deeply change during ICP rising. The main aim of this study was to evaluate the reliability and specificity of a novel method to calculate IEI (method C), based on the integral of the CSF pulse-wave area. Method: Twenty ventricular infusion-tests of patients with idiopathic NPH were re-evaluated. We have compared method C with the most widely used methods to calculate IEI: a modified Szewczykowski method (diastolic ICP against CSF pulse-wave amplitude-method A) and a modified Czosnyka method (diastolic ICP against the fundamental harmonic-method B). R-squared (R2) was calculated for each test. Means were compared through ANOVA and t-test. Results: Mean R2 values for methods A, B and C were 0.91 ± 0.06, 0.9 ± 0.06 and 0.96 ± 0.03, respectively. Mean R2 values obtained through method A vs C and through method B vs C were significantly different (p = .006 and p = .001, respectively), while values obtained through method A vs B were not (p = 1). Analysis of ICP tracks demonstrated that 9 patients showed no different shape of the ICP wave during the infusion test, while the remaining 11 did. The mean R2 values obtained through method A vs C and through method B vs C were significantly different (p < .001 for both) for patients showing a different shape of the ICP wave during the infusion test. Conclusions: Method C seems to be the most reliable method to calculate IEI, as it is independent from CSF pulse wave modifications.
Reference Key
md2014interdisciplinarya Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Carmelo Anile, MD;Pasquale De Bonis, PhD;Annunziato Mangiola, MD;Stefano Mannino, PhD;Pietro Santini
Journal advances in materials science and engineering
Year 2014
DOI
10.1016/j.inat.2014.03.002
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.