the effect of low flow inhalation anesthesia on operative hemodynamic condition in comparison with high flow anesthesia

Clicks: 135
ID: 178041
2007
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #74 of 83 articles by views in korean journal of food preservation

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Introduction & Objective: Low flow anesthesia technique in which the flow fresh gas is lower than minute volume of the patient results in improvement in the patient’s care such as reduction of operative hypothermia, reduction of postoperative shivering and leads to an increase in economical and enviornmental interests. The goal of the study was to investigate the patients’ operative hemodynamic variations using the high and low flow anesthesia techniques. Materials & Methods: This prospective, clincal and single blind study was carried out in Tbriz Emam Khomeini Hospital in 1384. In this study 97 patients in ASA class I or II after routine induction of G.A, during maintenance of anesthesia were randomly divided in two groups group I (high flow anesthesia) and group II (low flow anesthesia). For all patients ECG, HR, SPO2, BP, B.T, ETCO2 and inspiratory, expiratory percentage of O2, N2O, halothane, postoprative shievring and duration of oprations were recorded. 46 patients underwent high flow anesthesia and 51 patients underwent low flow anesthesia. Results: The average blood pressure in group I was as follow: preoperative, systol=13820 mmHg and diastol=7815 mmHg, intraoperative, systol=10531 mmHg and diastol=6410 mmHg and in recovery systol=11615 mmHg and diastol=7013 mmHg. In group II who had low flow anesthesia the blood pressure was found to be systol=13922 mmHg and diastol=7922 mmHg preoperative, systol=12221 mmHg and diastol=7517 mmHg intraoperative and systol=11815 mmHg and diastol=7717 mmHg in recovery. The differences in blood pressure in both group were statiscally significant (p=0.01). The average heart rate in group I was 9018 beat/min preoperative, 7014 intraoperative and 126 in recovery. The avrage heart rate in group II was 87.921 preoperative, 8616 intraoperative and 10417 in recovery. The differences were statiscally significant but there was no significant difference between the two groups with regard to sex, age and weight. Conclusion: Maintenance of anesthesia with low flow anesthesia gasses maintains more hemodynamic condition during operation.
Reference Key
eidi2007armaghanethe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;M Eidi;H Hoseinzade;KH Kolahdozan;D Aghamohammadi
Journal korean journal of food preservation
Year 2007
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.