loop mediated isothermal amplification for detection of trypanosoma brucei gambiense in urine and saliva samples in nonhuman primate model
Clicks: 202
ID: 177500
2015
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
202 views
18 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #395 of 1,324 articles by views in spectrochimica acta - part a: molecular and biomolecular spectroscopy
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,324 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Human African trypanosomiasis (HAT) is a vector-borne parasitic zoonotic disease. The disease caused by Trypanosoma brucei gambiense is the most prevalent in Africa. Early diagnosis is hampered by lack of sensitive diagnostic techniques. This study explored the potential of loop mediated isothermal amplification (LAMP) and polymerase chain reaction (PCR) in the detection of T. b. gambiense infection in a vervet monkey HAT model. Six vervet monkeys were experimentally infected with T. b. gambiense IL3253 and monitored for 180 days after infection. Parasitaemia was scored daily. Blood, cerebrospinal fluid (CSF), saliva, and urine samples were collected weekly. PCR and LAMP were performed on serum, CSF, saliva, and urine samples. The detection by LAMP was significantly higher than that of parasitological methods and PCR in all the samples. The performance of LAMP varied between the samples and was better in serum followed by saliva and then urine samples. In the saliva samples, LAMP had 100% detection between 21 and 77 dpi, whereas in urine the detection it was slightly lower, but there was over 80% detection between 28 and 91 dpi. However, LAMP could not detect trypanosomes in either saliva or urine after 140 and 126 dpi, respectively. The findings of this study emphasize the importance of LAMP in diagnosis of HAT using saliva and urine samples.
| Reference Key |
ngotho2015biomedloop
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Maina Ngotho;John Maina Kagira;Beatrice Muthoni Gachie;Simon Muturi Karanja;Maxwell Wambua Waema;Dawn Nyawira Maranga;Naomi Wangari Maina |
| Journal | spectrochimica acta - part a: molecular and biomolecular spectroscopy |