Evaluation of a hepatitis C virus core antigen assay from venepuncture and dried blood spot collected samples: a cohort study.
Clicks: 301
ID: 17620
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
72.0
/100
301 views
231 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #14 of 14 articles by views in journal of viral hepatitis
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The global scale-up of hepatitis C virus (HCV) diagnosis requires simplified and affordable HCV diagnostic pathways. This study evaluated the sensitivity and specificity of the HCV Architect core antigen (HCVcAg) assay for detection of active HCV infection in plasma and capillary whole-blood dried blood spots (DBS) compared to HCV RNA testing in plasma (Abbott RealTime HCV Viral Load). Samples were collected from participants in an observational cohort enrolled at three sites in Australia (two drug treatment and alcohol clinics and one homelessness service). Of 205 participants, 200 had results across all samples and assay types and 186 were included in this analysis (14 participants receiving HCV therapy were excluded). HCV RNA was detected in 29% of participants ([95% CI 22.6-36.1], 54 of 186). The sensitivity of HCVcAg for detection of active HCV infection in plasma was 98.1% (95% CI 90-100) and 100% (95% CI 93-100) when compared to HCV RNA thresholds of ≥12 IU/mL and ≥1,000 IU/mL respectively. The sensitivity of the HCVcAg assay for detection of active HCV infection in DBS was 90.7% (95% CI 80-97) and 92.5% (95% CI 82-98) when compared to HCV RNA thresholds of ≥12 IU/mL and ≥1,000 IU/mL respectively. The specificity of HCV core antigen for detection of active infection was 100% (95% CI 97-100) for all samples and RNA thresholds. These data indicate that the detection of HCVcAg is a useful tool for determining active HCV infection; to facilitate enhanced testing, linkage to care and treatment particularly when testing plasma samples are collected by venepuncture. This article is protected by copyright. All rights reserved.
| Reference Key |
catlett2019evaluationjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Catlett, Beth;Lamoury, Francois M J;Bajis, Sahar;Hajarizadeh, Behzad;Martinez, Danica;Mowat, Yasmin;Cunningham, Philip H;Jacka, Brendan P;Cloherty, Gavin A;Marks, Philippa;Dore, Gregory J;Grebely, Jason;Applegate, Tanya L; |
| Journal | journal of viral hepatitis |
| Year | 2019 |
| DOI |
10.1111/jvh.13196
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.