Pharmaceutical Pill Counting and Inspection Using a Capacitive Sensor
Clicks: 339
ID: 17611
2008
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Popular Article
63.7
/100
339 views
235 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
PopularRanked #9 of 17 articles by views in sensors & transducers
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A capacitive sensor for high-speed counting and inspection of pharmaceutical products is proposed and evaluated. The sensor is based on a patented Electrostatic Field Sensor (EFS) device, previously developed by Sparc Systems Limited. However, the sensor head proposed in this work has a significantly different geometry and has been designed with a rectangular inspection aperture of 160mm × 21mm, which best meets applications where a larger count throughput is required with a single sensor. Finite element modelling has been used to simulate the electrostatic fields generated within the sensor, and as a design tool for optimising the sensor head configuration. The actual and simulated performance of the sensor is compared and analysed in terms of the sensor performance at discriminating between damaged products or detection of miscount errors.
| Reference Key |
letchumanan2008pharmaceuticalsensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | LETCHUMANAN, Ganesan;HAWKINS, Simon;ROCKETT, Peter;SHEARD, Steve;SHAIL, Conrad;SHAIL, Kenneth;DOBSON, Peter; |
| Journal | sensors & transducers |
| Year | 2008 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations