vaginal repair of cystocele with anterior wall mesh via transobturator route: efficacy and complications with up to 3-year followup

Clicks: 133
ID: 175399
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #27 of 33 articles by views in electronic journal of biotechnology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Study Objective. The objective of this study was to report on the safety and efficacy of cystocele repair with anterior wall mesh placed via a transobturator route (Perigee system, AMS, Minnetonka, MN). Design. Single center retrospective study. Setting. Single center hospital setting and Urogynecology practice in the United States. Patients. 77 women presenting with symptomatic anterior wall prolapse. Intervention. Repair of cystocele with an anterior wall Type I soft-polypropylene mesh placed via a transobturator approach. Concomitant procedures in other compartment were also completed as indicated. Measurements and Main Results. 77 women underwent the Perigee procedure at our institution over a 2-year period. The mesh was attached to the pelvic sidewalls at the level of the bladder neck and near the ischial spine apically with needles passed through the groins and obturator space. Mean follow-up was 18.2 months (range 3–36 months). Objective cure rate was 93%. Subjectively only two patients have had recurrent symptoms of prolapse, and only 1 of these has required repeat surgery for cystocele. Mesh exposure vaginally occurred in 5 patients (6.5%); however all were treated with estrogen and/or local excision of exposed mesh and had no further sequelae. There were no incidences of chronic pain, infection, or abscess, and no patient required complete mesh removal for infection, pain, or extrusion. Conclusion. In select patients with anterior wall prolapse, repair with mesh augmentation via the transobturator route is a safe and effective procedure with up to 3 years of follow-up.
Reference Key
moore2009advancesvaginal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Robert D. Moore;John R. Miklos
Journal electronic journal of biotechnology
Year 2009
DOI
10.1155/2009/743831
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.