noninvasive measurement of cardiac performance in recovery from exercise in heart failure patients

Clicks: 462
ID: 175000
2011
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #7 of 128 articles by views in icitacee 2015 - 2nd international conference on information technology, computer, and electrical engineering: green technology strengthening in information technology, electrical and computer engineering implementation, proceedings

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 128 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
OBJECTIVE: To examine the association between cardiac performance during recovery and the severity of heart failure, as determined by clinical and cardiopulmonary exercise test responses. METHODS: As part of a retrospective cohort study, 46 heart failure patients and 13 normal subjects underwent cardiopulmonary exercise testing while cardiac output was measured using a noninvasive device. Cardiac output in recovery was expressed as the slope of a single exponential relationship between cardiac output and time; the recovery-time constant was assessed in relation to indices of cardiac function, along with clinical, functional, and cardiopulmonary exercise responses. RESULTS: The recovery time constant was delayed in patients with heart failure compared with normal subjects (296.7 + 238 vs. 110.1 +27 seconds, p <0.01), and the slope of the decline of cardiac output in recovery was steeper in normal subjects compared with heart failure patients (p,0.001). The slope of the decline in cardiac output recovery was inversely related to peak VO2 (r = -0.72, p<0.001) and directly related to the VE/VCO2 slope (r = 0.57, p,0.001). Heart failure patients with abnormal recovery time constants had lower peak VO2, lower VO2 at the ventilatory threshold, lower peak cardiac output, and a heightened VE/VCO2 slope during exercise. CONCLUSIONS: Impaired cardiac output recovery kinetics can identify heart failure patients with more severe disease, lower exercise capacity, and inefficient ventilation. Estimating cardiac output in recovery from exercise may provide added insight into the cardiovascular status of patients with heart failure.
Reference Key
myers2011clinicsnoninvasive Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Jonathan N Myers;Pradeep Gujja;Suresh Neelagaru;Leon Hsu;Daniel Burkhoff