o uso de técnica eletroquímica para a descontaminação de estruturas cerâmicas vítreas porosas the use of electrochemical technique for porous vitreous ceramic structure decontamination

Clicks: 285
ID: 173938
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #20 of 111 articles by views in Zootaxa

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Apresentamos neste trabalho os resultados de ensaios preliminares para avaliar o uso de técnica de eletro-osmose para a remoção de contaminantes orgânicos em estruturas porosas cerâmicas, como filtros ou similares. A técnica consiste em forçar a migração de contaminantes retidos na estrutura interna ou na superfície dos poros por meio da aplicação de tensão controlada em célula eletroquímica projetada para este fim. As moléculas absorvidas na superfície cerâmica estarão sujeitas as ações cisalhantes de uma camada aquosa difusa móvel, e uma vez na condição iônica, migram na direção do campo de carga oposta, sendo posteriormente removidas. Nos ensaios de avaliação da técnica, escolhemos o fenol como contaminante padrão e os testes realizados em membranas vítreas microporosas imersas em solução aquosa. Os dados foram obtidos em função do tempo de aplicação da carga por medidas de densidade ótica e concentração de hidrogenação. Os resultados indicam remoções proporcionais a 70% do contaminante em estado diluído após 120 min de aplicação de carga.
In this study the preliminary results of the use of electro-osmosis technique for the removal of organic contaminants in porous ceramic structure is presented. The method consists in provoke the migration of chemicals retained in the structure or adsorbed on the pores surfaces by application of a controlled tension in an electrochemical cell. The adsorbed molecules underwent shear stress due to a diffuse moving layer, which once in ionic state, the specimens are dragged and move towards the opposite charged electrode. Phenol was chose as standard contaminant and the tests carried out in vitreous porous membranes. The testes were performed in function of charge application and concentration assessed by optical densities. The results show a proportional removal of 70% of the contaminant in diluted condition after 120 min of charge application.
Reference Key
assis2010cermicao Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager