Papel da ranitidina como meio de aprimorar a qualidade do exame de colangiopancreatografia por ressonância magnética The role of ranitidine in the enhancement of imaging quality in magnetic resonance cholangiopancreatography
Clicks: 519
ID: 17348
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
85.3
/100
519 views
379 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1 of 4 articles by views in radiologia brasileira
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
OBJETIVO: Avaliar o impacto da ranitidina por via oral na qualidade do exame de colangiopancreatografia por ressonância magnética (CPRM). MATERIAIS E MÉTODOS: Trinta e dois pacientes realizaram CPRM com aquisições 3D e 2D, com três estratégias de supressão do sinal líquido gastrintestinal: a) apenas em jejum; b) 12 horas após ingerir 300 mg de ranitidina; c) após a ingestão de solução de gadolínio. Três observadores avaliaram os estudos, atentos para o grau de visualização da árvore biliopancreática. Foi medida a concordância interobservador com o teste kappa. A diferença entre técnicas e formas de aquisição foi avaliada pela média da soma dos escores de graduação. RESULTADOS: As três estratégias de supressão do sinal líquido gastrintestinal apresentaram elevada reprodutibilidade. A supressão do sinal líquido gastrintestinal com a ranitidina foi semelhante ao jejum e ambas foram piores do que a solução de gadolínio. As aquisições 3D superaram a 2D apenas na visualização do ducto cístico e da vesícula biliar, sendo inferior ou equivalente nos demais segmentos ductais biliopancreáticos. CONCLUSÃO: O uso da ranitidina não parece justificado para aprimorar a avaliação da árvore biliopancreática em exames de CPRM. A CPRM 2D apenas em jejum permite a visualização ductal com elevada qualidade e reprodutibilidade na maioria dos casos.
OBJECTIVE: To assess the impact of oral ranitidine on the imaging quality in magnetic resonance cholangiopancreatography (MRCP). MATERIALS AND METHODS: Thirty-two patients underwent MRCP with 3D and 2D acquisitions, and three strategies for suppression of the gastrointestinal fluid signal: a) only at fasting; b) 12 hours after ingestion of 300 mg ranitidine; c) after oral administration of gadolinium solution. Three observers reviewed the images with a focus on the degree of visualization of the biliopancreatic tree. The interobserver agreement was evaluated with the kappa test. The difference between techniques and acquisition modalities were evaluated by means of average grading scores. RESULTS: The three strategies for suppression of the gastrointestinal fluid signal presented high reproducibility. The results with suppression of the gastrointestinal fluid signal with ranitidine where similar to those obtained with fasting, and both were worse than those obtained with gadolinium solution. The 3D acquisitions surpassed 2D only in terms of visibility of the cystic duct and gallbladder, and were inferior or equivalent in the other biliopancreatic ductal segments. CONCLUSION: The use of ranitidine does not seem justified in the evaluation of the biliopancreatic tree at MRCP, since 2D MRCP with fasting allows the visualization of ductal structures with high quality and reproducibility in the majority of cases.
OBJECTIVE: To assess the impact of oral ranitidine on the imaging quality in magnetic resonance cholangiopancreatography (MRCP). MATERIALS AND METHODS: Thirty-two patients underwent MRCP with 3D and 2D acquisitions, and three strategies for suppression of the gastrointestinal fluid signal: a) only at fasting; b) 12 hours after ingestion of 300 mg ranitidine; c) after oral administration of gadolinium solution. Three observers reviewed the images with a focus on the degree of visualization of the biliopancreatic tree. The interobserver agreement was evaluated with the kappa test. The difference between techniques and acquisition modalities were evaluated by means of average grading scores. RESULTS: The three strategies for suppression of the gastrointestinal fluid signal presented high reproducibility. The results with suppression of the gastrointestinal fluid signal with ranitidine where similar to those obtained with fasting, and both were worse than those obtained with gadolinium solution. The 3D acquisitions surpassed 2D only in terms of visibility of the cystic duct and gallbladder, and were inferior or equivalent in the other biliopancreatic ductal segments. CONCLUSION: The use of ranitidine does not seem justified in the evaluation of the biliopancreatic tree at MRCP, since 2D MRCP with fasting allows the visualization of ductal structures with high quality and reproducibility in the majority of cases.
| Reference Key |
torres2013papelradiologia
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Torres, Lucas Rios;Bretas, Elisa Almeida Sathler;Filho, Galvani Ascar Sauaia;Soares, Adriano Fleury de Faria;D'Ippolito, Giuseppe; |
| Journal | radiologia brasileira |
| Year | 2013 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.