effects of sp2/sp3 ratio and hydrogen content on in vitro bending and frictional performance of dlc-coated orthodontic stainless steels

Clicks: 233
ID: 173087
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #32 of 58 articles by views in die pharmazie

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This study investigated a diamond-like carbon (DLC) coating formed on stainless steels (disk and wire specimens) using a plasma-based ion implantation/deposition method with two different parameters (DLC-1, DLC-2). These specimens were characterized using high-resolution elastic recoil analysis, microscale X-ray photoelectron spectroscopy and nanoindentation testing to determine the hydrogen content, sp2/sp3 ratio and mechanical properties of the coating. Three-point bending and frictional properties were estimated. DLC-1 had a diamond-rich structure at the external surface and a graphite-rich structure at the inner surface, while DLC-2 had a graphite-rich structure at the external surface and a diamond-rich structure at the inner surface. Mean mechanical property values obtained for the external surface were lower than those for the inner surface in both types of DLC-coated specimens. The hydrogen content of DLC-2 was slightly higher versus DLC-1. Both DLC-coated wires produced a significantly higher elastic modulus according to the three-point bending test versus the non-coated wire. DLC-2 produced significantly lower frictional force than the non-coated specimen in the drawing-friction test. The coating of DLC-1 was partially ruptured by the three-point bending and drawing-friction tests. In conclusion, the bending and frictional performance of DLC-coated wire were influenced by the hydrogen content and sp2/sp3 ratio of the coating.
Reference Key
muguruma2018coatingseffects Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Takeshi Muguruma;Masahiro Iijima;Masahiro Kawaguchi;Itaru Mizoguchi
Journal die pharmazie
Year 2018
DOI
10.3390/coatings8060199
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.