the use of pacemakers in infants and children
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #167 of 231 articles by views in planta medica
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 231 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
Background: To review retrospectively our experience with pediatric cardiac pacing with an emphasis on specific problems in pacemaker implantation in infants and children.
Methods: Between April 1977 and March 2005 ninety-one child underwent permanent pacemaker implantation, 46 boys (50.5%) and 45 girls (49.5) with a mean age of 7.9 years (the oldest 17 years and the youngest 1 day). The age of the children at the time of implantation was 2 to 9 years in one half and 14 to 17 years in one fourth of them. Five children were younger than one month and three of them younger than one week. The indications for permanent pacing were complete atrioventricular block (CAVB) in more than half patients, sick sinus syndrome in one fourth and CAVB following open heart surgery in nine. The mean time for elective battery replacement was 6.5 years after the implantation. In one third of the children the battery was replaced before the end of the fifth year after the implantation and after seven years in more than half of the patients. Epicardial leads and left anterior thoracotomy or subxyphoid approach were used at the beginning. From the year 1980 we prefered transvenous leads. Modern epicardial steroideluting leads demonstrated relatively stable acute and chronic pacing and sensing tresholds. VVI/R pacemaker was the pacemaker of choice at the first implantation and we upgraded the pacing at the time of the elective battery replacement. Children with VDD pacemakers needed sometimes upgrading of pacing sooner because of the inappropriate atrial sensing and AV synchronyzation.
Conclusions: Better quality pacing leads and smaller but more powerful pacemaker generators with autocapturecontrolled pacing options became more and more attractive for our little patients because of better implantation facilities, substantial energy savings and battery life prolongation.
| Reference Key |
kosin2005zdravnikithe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | |
| Journal | planta medica |
| Year | 2005 |
| DOI |
DOI not found
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.