quantitative and enantioselective analysis of monoterpenes from plant chambers and in ambient air using spme

Clicks: 258
ID: 172646
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #23 of 183 articles by views in bioorganic & medicinal chemistry

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) system has been developed for quantifying enantiomeric and nonenantiomeric monoterpenes in plant chamber studies and ambient air. Performance of this system was checked using a capillary diffusion system to produce monoterpene standards. The adsorption efficiency, competitive adsorption and chromatographic peak resolution of monoterpene enantiomer pairs were compared for three SPME fibre coatings: 75 μm Carboxen-PDMS (CAR-PDMS), 50/30 μm divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) and 65 μm divinylbenzene-polydimethylsiloxane (DVB-PDMS). Key parameters such as the linearity and reproducibility of the SPME system have been investigated in this work. The best compromise between the enantiomeric separation of monoterpenes and competitive adsorption of the isoprenoids on the solid SPME fibre coating was found for DVB-PDMS fibres. The optimum conditions using DVB-PDMS fibres were applied to measure the exchange rates of monoterpenes in the emission of <i>Quercus ilex</i> using a laboratory whole plant enclosure under light and dark conditions, as well as in ambient air. With 592 and 223 ng m<sup>−2</sup> s<sup>−1</sup> respectively, &beta;-myrcene and limonene were the predominant monoterpenes in the emission of <i>Q. ilex</i>. These values were closely comparable to those obtained using a zNose and cartridge GC-FID systems.
Reference Key
yassaa2010atmosphericquantitative Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;N. Yassaa;T. Custer;W. Song;F. Pech;J. Kesselmeier;J. Williams
Journal bioorganic & medicinal chemistry
Year 2010
DOI
10.5194/amt-3-1615-2010
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.