very high cycle fatigue behavior of ta11 titanium alloy

Clicks: 201
ID: 171199
2017
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
The conventional fatigue test method was used to obtain the very high cycle fatigue (VHCF) limits of 3×107 and 1×108 cycles for TA11 titanium alloy in different temperatures and stress ratios. Three parameter power function method was used to obtain the VHCF median S-N curves and equations. The results show that the VHCF strength of 3×107 and 1×108 cycles presented a continue reducing trend compared with the traditional 1 x 107 fatigue limit. This trend is not obvious in negative stress ratio (R=-1), but significant in normal stress ratio (R=0.1 and 0.5), and the reduction amplitude of room temperature tests was greater than that of elevated temperature tests. The fracture morphologies showed that the VHCF cracks initiat at the specimen surface of TA11 alloy in room temperature tests, and the VHCF cracks initiation ways in elevated temperature tests relate to the stress ratio. The cracks initiate at the specimen surface when R=0.1 and 0.5 but in the internal when R=0.5; The surface state of TA11 alloy specimens is the main cause of its fatigue life dispersion.
Reference Key
zehui2017journalvery Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;JIAO Zehui;YU Huichen;ZHONG Bin;LI Xudong;ZHOU Jingyi
Journal law and human behavior
Year 2017
DOI
10.11868/j.issn.1005-5053.2016.000113
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.