Development of a high-throughput assay to measure measles neutralizing antibodies.
Clicks: 208
ID: 17115
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
76.2
/100
208 views
170 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #1,617 of 2,056 articles by views in PloS one
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 2,056 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Measles virus is highly infectious and remains a leading cause of vaccine preventable deaths in children. Neutralizing antibody responses elicited by measles virus infection or immunization are a serological correlate of protection. We describe a high-throughput neutralization assay to improve surveillance for measles immunity. Measles virus-antibody mixtures were incubated on Vero cell monolayers and 24 hours later cell-lysates harvested and subjected to one-step SYBR green RT-qPCR to amplify a target sequence within the measles virus nucleoprotein gene. Neutralization endpoint titers were interpolated to determine the dilution that inhibited the relative amplicon copy number by at least 90% compared to the mean signal obtained in virus control wells in the absence of serum. Anti-measles virus and anti-measles hemagglutinin antisera specifically neutralized measles virus in the microneutralization RT-qPCR assay while pre-immune sera and sera raised against other viruses did not. The microneutralization RT-qPCR assay obeyed the Percentage Law for measles virus inputs ranging from 100-5000 TCID50/well. The linear range of the assay corresponds to measles antibody concentrations of 30 to 3000 mIU/mL. Bland-Altman analysis and two-way analysis of variance demonstrated that results obtained using the microneutralization RT-qPCR assay were comparable to those obtained using a plaque reduction neutralization test and correctly identified human serum samples that were seropositive (95% and 100%, sensitivity and specificity, respectively). Furthermore, these comparisons suggest that a concentration of 300 mIU/mL may be a conservative cut-point to use to identify individuals likely to be protected against severe measles disease when the endpoint is based on 90% inhibition of virus replication. Measles virus microneutralization RT-qPCR is a rapid, sensitive, specific, and robust assay for detecting measles neutralizing antibodies that may help to improve immunization strategies nationally and achieve measles elimination globally.
| Reference Key |
alvaradofacundo2019developmentplos
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Alvarado-Facundo, Esmeralda;Audet, Susette;Moss, William J;Beeler, Judy A; |
| Journal | PloS one |
| Year | 2019 |
| DOI |
10.1371/journal.pone.0220780
|