hızlandırıcılardan yayınlanan Çatı radyasyonunun uzaklığa bağlı doz değerleri

Clicks: 47
ID: 170608
2012
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #40 of 49 articles by views in clinical chemistry

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Özet: Yeterli zırhlama durumlarının çoğu yatay doğrultuda sağlandığı için, ince çatı zırhı, bazı hızlandırıcılarda uğraşılan önemli bir problemi göstermektedir. Çatı radyasyonu, hareket doğrultusu yukarı doğru yer yüzeyine yakın yerlerde oluşan ve sonra atmosferdeki moleküller tarafından geri saçılan radyasyon (genellikle nötronlar) için kullanılan bir terimdir. Hızlandırıcı çevresinde yaşayan halk, bu radyasyondan etkilenebilir. Bu etkiyi belirlemek için, nötronların havada yer değiştirme hesapları sık sık kullanılmaktadır. Bu çalışmada, yüksek enerjili hızlandırıcılardan yayınlanan çatı radyasyonunun uzaklığın bir fonksiyonu olarak doz değerleri hesaplandı. Anahtar kelimeler: Hızlandırıcılar, çatı radyasyonu, doz değerleri. Abstract: Thin roof shielding has represented a serious problem that plagued a number of accelerators, because in most cases sufficient shielding must be provided in the horizontal direction. Skyshine is the term used for radiation (usually neutrons) that originates near the surface of the earth with an upward velocity and then is scattered back by the molecules in the atmosphere. The public around the accelerator may be irradiated. To estimate this exposure, tabulated solutions of the transport of neutrons through the air are frequently used. In this study, we calculated the dose values as a function of distance of skyshine radiation from high-energy accelerators. Key words: Accelerators, skyshine radiation, dose values.
Reference Key
ker2012sleymanhzlandrclardan Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Rahmi Küçer;Demet Sarıyer;Nermin Küçer
Journal clinical chemistry
Year 2012
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.