transferência de oxigênio em reatores de leito fluidizado com circulação em tubos concêntricos em meios bifásico e trifásico com variação da relação entre diâmetros oxygen transfer in two and three-phase internal-loop airlift reactor with riser diameter variation

Clicks: 269
ID: 168527
2010
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #15 of 36 articles by views in ophthalmology and therapy

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
A eficiência do reator de leito fluidizado com circulação em tubos concêntricos depende das condições hidrodinâmicas que influem na transferência de oxigênio ao biofilme. Este trabalho investigou a influência da relação entre diâmetros dos tubos e da concentração de meio suporte (areia), sobre o coeficiente global de transferência de oxigênio (K La). Os ensaios - em reatores de 2,6 m de altura, com diâmetro externo de 250 mm e internos de 100, 125, 150 e 200 mm - empregaram vazões de ar até 2.500 L.h-1 e concentrações de até 150 g.L-1 de areia. O K La aumentou ligeiramente com 30 g.L-1 e diminuiu para concentrações maiores, confirmando relatos da literatura em condições semelhantes. Um modelo para K La em meio bifásico foi ajustado para as diversas relações ensaiadas entre a área externa e a interna, postulando-se uma redução na razão entre a transferência na fase líquida e o diâmetro da bolha com o aumento da vazão de ar.
The efficiency of the concentric tubes internal-loop airlift reactor depends on the hydrodynamic conditions that affect oxygen transfer to the biofilm. This work studied the effects of the relation between diameters of the tubes and of the carrier (sand) concentration on the global oxygen transfer coefficient (K La). The tests - in 2,6 m high reactors with 250 mm external diameter and 100, 125, 150 and 200 mm internal diameters - were performed with air flow taxes up to 2,500 L.h-1 and sand concentrations up to 150 g.L-1. The K La increased slightly for 30 g.L-1 and decreased for higher concentrations, in accordance with related data for similar conditions. A model for K La in biphasic medium was fitted embracing all the external/internal area relationships tested, based on the reduction of the liquid phase transfer coefficient and the bubble diameter ratio with increasing air flow rates.
Reference Key
arajo2010engenhariatransferncia Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager