apical microleakage of epoxy resin and methacrylate resin-based sealer with continuous wave obturation technique
Clicks: 182
ID: 167620
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
182 views
17 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #73 of 103 articles by views in The Journal of organic chemistry
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The aim of this research was to determine the microleakage apical sealer based on epoxy resin and methacrylate resin with continuous wave obturation technique.Thirty permanent lateral incisors were selected at random and divided into 3 groups (N=10), namely AH Plus obturator group (epoxy resin), EndoREZ group (methacrylate resin), and negative control. The samples were decoronated, root canal preparation, then kept in incubator of 37°C for 72 hours. Sample were coated with nail varnish then immersed in methylene blue for 48 hours. The samples were washed with distilled water, dried and nail varnish removed. The samples were clearing. Penetration was measured using microscope and given score 0-4. Measurements were analyzed statistically. By using Kruskal Wallis test and Mann Whitney test, there is no significant difference between the apical microleakage of the the epoxy resin root canal sealer with methacrylate root canal sealer based (p>0,05). It means that the apical microleakage of the epoxy resin root canal sealer based comparable with merhacrylate root canal sealer based. It was concluded that the apical microleakage of epoxy resin based sealer does not different to the methacrylate resin based sealer
| Reference Key |
haslinda2016journalapical
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Haslinda Haslinda;Christine Anastasia Rovani;Aries Chandra Trilaksana |
| Journal | The Journal of organic chemistry |
| Year | 2016 |
| DOI |
10.15562/jdmfs.v1i1.19
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.