proposal how to reconstruct the roŠka multi-storey

Clicks: 76
ID: 166828
2013
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #9 of 10 articles by views in chemische berichte

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
We have known for years that the residential towers on Roška Street are absolutely the most problematic buildings in Ljubljana in terms of their seismic safety. We decided to propose the rehabilitation of these structures in line with a "new philosophy" according to which the building interiors are left unaffected, and all the necessary reinforcements are implemented externally. During rehabilitation works, the building is not deprived of its habitational function. We developed the "nothing within – all without" philosophy back in 1981 for the rehabilitation of a big hotel near Makarska (we also took out a patent for it then). It is also essential to note that, apart from adequate seismic reinforcement, we gain new residential floor areas which generally cover all rehabilitation costs. In the case of the residential towers on Roška Street, we envisaged additional reinforced concrete walls for the entire perimeter of the towers. These walls are "stabilised" with a 3 m wide console slab running all around each floor, thus adding approximately 65 sqm of additional floor area to every apartment, which amounts to a little more than the net apartment floor area. Before setting up the new additional perimeter walls, we place 15 cm of insulation in between which considerably reduces the use of heating energy and eliminates all "thermal bridges". The old perimeter walls are connected to the new ones by Ø 22 mm inox steel treenails (with weak thermal conductivity). Since the existing structures are no longer settling, all of the new perimeter walls will be founded on Jet-Grouted columns.
Reference Key
vogelnik2013ar:proposal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Blaž Vogelnik
Journal chemische berichte
Year 2013
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.