preconcentration with 1-nitroso-2-naphthol complexes on dowex mwc-1 resin: determination of cu and zn at trace level in drinking water samples by icp-aes
Clicks: 186
ID: 166102
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
186 views
22 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #95 of 235 articles by views in Journal of pharmaceutical and biomedical analysis
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 235 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
In this study, copper(II) and zinc(II) were quantitatively determined in drinking water using ICP-AES after preconcentration. For this purpose, the water samples were treated with 1-nitroso-2-naphthol to form metal complexes on Dowex MWC-1 resin. Prior to the sorption process, the column was treated with a chelating resin Dowex MWC-1 and the column was prepared by passing buffer solution at different pH values. These columns were used for the transportation of water samples through the resin at the flow rate of 2.00 mL min-1. The effluents were then analyzed by ICP-AES using standard addition method. The effect of pH, amount of resin, ligand concentration and eluent type were investigated. The detection limit for Cu(II) and Zn(II) were found to be 2.78 μg L-1and 6.34 μg L-1 respectively (RSD.’s <%5).it would be concluded that the determination of copper(II) and zinc(II) in drinking water was simple, fast and repliable using this technique.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (131 words).
Try re-searching for a better abstract.
| Reference Key |
mulazimoglu2009e-journalpreconcentration
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;A. Demir Mulazimoglu;I. E. Mulazimoglu;E. Ozkan |
| Journal | Journal of pharmaceutical and biomedical analysis |
| Year | 2009 |
| DOI |
10.1155/2009/734525
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.