Implementation of Epic Beaker Clinical Pathology at an academic medical center

Clicks: 272
ID: 16567
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #6 of 7 articles by views in Journal of pathology informatics

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Background: Epic Beaker Clinical Pathology (CP) is a relatively new laboratory information system (LIS) operating within the Epic suite of software applications. To date, there have not been any publications describing implementation of Beaker CP. In this report, we describe our experience in implementing Beaker CP version 2012 at a state academic medical center with a go-live of August 2014 and a subsequent upgrade to Beaker version 2014 in May 2015. The implementation of Beaker CP was concurrent with implementations of Epic modules for revenue cycle, patient scheduling, and patient registration. Methods: Our analysis covers approximately 3 years of time (2 years preimplementation of Beaker CP and roughly 1 year after) using data summarized from pre- and post-implementation meetings, debriefings, and the closure document for the project. Results: We summarize positive aspects of, and key factors leading to, a successful implementation of Beaker CP. The early inclusion of subject matter experts in the design and validation of Beaker workflows was very helpful. Since Beaker CP does not directly interface with laboratory instrumentation, the clinical laboratories spent extensive preimplementation effort establishing middleware interfaces. Immediate challenges postimplementation included bar code scanning and nursing adaptation to Beaker CP specimen collection. The most substantial changes in laboratory workflow occurred with microbiology orders. This posed a considerable challenge with microbiology orders from the operating rooms and required intensive interventions in the weeks following go-live. In postimplementation surveys, pathology staff, informatics staff, and end-users expressed satisfaction with the new LIS. Conclusions: Beaker CP can serve as an effective LIS for an academic medical center. Careful planning and preparation aid the transition to this LIS.
Reference Key
krasowski2016implementationjournal Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Krasowski, Matthew D;Wilford, Joseph D;Howard, Wanita;Dane, Susan K;Davis, Scott R;Karandikar, Nitin J;Blau, John L;Ford, Bradley A;
Journal Journal of pathology informatics
Year 2016
DOI
DOI not found
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.