development of a unified reversed-phase hplc method for efficient determination of ep and usp process-related impurities in celecoxib using analytical quality by design principles

Clicks: 249
ID: 165323
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Emerging

Ranked #630 of 1,183 articles by views in Journal of ethnopharmacology

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 1,183 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
This article presents the development of a reversed-phase (RP) high-performance liquid chromatographic (HPLC) method for determination of process-related impurities in a celecoxib drug substance following Analytical Quality by Design (AQbD) principles. The method from European Pharmacopeia (EP) for celecoxib drug substance does not sufficiently separate celecoxib from its EP impurity B because the system suitability criterion is not achieved (resolution NLT 1.8). The same issue was observed with the proposed method from United States Pharmacopeia (USP) for celecoxib capsules, where EP impurity A elutes under the main peak. A new HPLC method was developed that eliminates the disadvantages of the two pharmacopeial methods and is capable of efficiently separating and determining all seven impurities listed in EP and the proposed USP monographs. The development of a new HPLC method started with method scouting, in which various C18 and phenyl stationary phases were tested. Improved selectivity was obtained only with a chiral stationary phase. An immobilized Chiralpak IA-3 column used in RP mode turned out to be the most appropriate for method optimization. The ratio of acetonitrile in the mobile phase, flow rate, and column temperature were recognized as critical method parameters (CMPs) and were further investigated using a central composite face response-surface design. A multiple linear regression (MLR) method was applied to fit the mathematical models on the experimental data to determine factor−response relationships. The models created show adequate fit and good prediction abilities. The Monte Carlo simulation method was used to establish the design space. The method developed was verified in terms of precision, sensitivity, accuracy, and linearity, and the results showed that the new method is suitable for determination of seven process-related impurities of celecoxib.
Reference Key
tome2020moleculesdevelopment Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Tim Tome;Zdenko Časar;Aleš Obreza
Journal Journal of ethnopharmacology
Year 2020
DOI
10.3390/molecules25040809
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.