validade do teste de 30 minutos (t-30) na determinação da capacidade aeróbia, parâmetros de braçada e performance aeróbia de nadadores treinados validity of 30 minutes test (t-30) in aerobic capacity, stroke parameters and aerobic performance determination of trained swimmers
Article Quality & Performance Metrics
Readership in this journal
SteadyRanked #25 of 73 articles by views in research disclosure
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
Abstract
The aim of the present study was to verify the use of the 30 minutes velocity (VT-30), stroke rate (SR), stroke length (SL) and stroke index (SI), obtained in T-30 test, as non-invasive methods for trained swimmer's aerobic performance and technical determination. Fourteen swimmers accomplished three efforts along 400 m (85, 90 and 100% of the maximum effort) for anaerobic threshold speed determination (ATS) corresponding to 3.5 mM lactate fixed concentration, as well as a 30 minutes maximal effort (VT-30). SR, SL, and SI were calculated within the 10 m midsection of the swimming pool (clean swim) for T-30 test (SRT-30, SLT-30 and SIT-30) and progressive test. Through the relation between ATS and stroke parameters in progressive test, stroke rate threshold (SRT), stroke length threshold (SLT) and stroke index threshold (SIT) were determined. The time to complete 400 m at maximal effort was considered as performance parameter (P400). No significant difference was found between the ATS (1.29 ± 0.07 m.s-1) and VT-30 (1.29 ± 0.08 m.s-1), along with a correlation (r = 0.90). The values of SRT (33.6 ± 4.14 cycles/min) and SRT-30 (34.9 ± 3.53 cycles/min) and of SLT (2.09 ± 0.20 m/cycle) and SLT-30 (2.09 ± 0.20 m/cycle) also had no significant differences. Significant correlations (p < 0.05) were also found between VT-30 and P400 (r = 0.95); SRT and SRT-30 (r = 0.73); SLT and SLT-30 (r = 0.89) and SIL and SIT-30 (r = 0.94). It was concluded that the VT-30 shows reliability for training monitoring, performance prediction and technical parameters determination in swimmers.
| Reference Key |
deminice2007revistavalidade
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Rafael Deminice;Marcelo Papoti;Alessandro Moura Zagatto;Milton Vieira do Prado Júnior |
| Journal | research disclosure |
| Year | 2007 |
| DOI |
10.1590/S1517-86922007000300013
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
ZincirX productsfrom the team behind Journament
-
PatentYazar
Patent drafts for the EPO, USPTO and TürkPatent
From inventor notes to a DOCX draft: description, claims, abstract. The machine drafts, the attorney signs.
See how it works (opens in a new tab) -
Projenator
Have a project idea? Score and plan it with AI
AI scores your idea in five dimensions and builds a phased plan. Your first project is free, no card needed.
Start your first project (opens in a new tab)
Cookies
We use strictly necessary cookies to run the site and keep you signed in. With your permission we would also use Google Analytics to see how the site is used, and Google AdSense to show ads on journal and article pages. Both stay off unless you accept, and you can change your mind at any time. How we use cookies · KVKK notice (Türkiye)
Cookie settings
Comments
No comments yet. Be the first to comment on this article.