quality assessment of platelet concentrates prepared by platelet rich plasma-platelet concentrate, buffy coat poor-platelet concentrate (bc-pc) and apheresis-pc methods

Clicks: 252
ID: 165057
2009
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
Background: Platelet rich plasma-platelet concentrate (PRP-PC), buffy coat poor-platelet concentrate (BC-PC), and apheresis-PC were prepared and their quality parameters were assessed. Study Design: In this study, the following platelet products were prepared: from random donor platelets (i) platelet rich plasma - platelet concentrate (PRP-PC), and (ii) buffy coat poor- platelet concentrate (BC-PC) and (iii) single donor platelets (apheresis-PC) by different methods. Their quality was assessed using the following parameters: swirling, volume of the platelet concentrate, platelet count, WBC count and pH. Results: A total of 146 platelet concentrates (64 of PRP-PC, 62 of BC-PC and 20 of apheresis-PC) were enrolled in this study. The mean volume of PRP-PC, BC-PC and apheresis-PC was 62.30±22.68 ml, 68.81±22.95 ml and 214.05±9.91 ml and ranged from 22-135 ml, 32-133 ml and 200-251 ml respectively. The mean platelet count of PRP-PC, BC-PC and apheresis-PC was 7.6±2.97 x 1010/unit, 7.3±2.98 x 1010/unit and 4.13±1.32 x 1011/unit and ranged from 3.2-16.2 x 1010/unit, 0.6-16.4 x 1010/unit and 1.22-8.9 x 1011/unit respectively. The mean WBC count in PRP-PC (n = 10), BC-PC (n = 10) and apheresis-PC (n = 6) units was 4.05±0.48 x 107/unit, 2.08±0.39 x 107/unit and 4.8±0.8 x 106/unit and ranged from 3.4 -4.77 x 107/unit, 1.6-2.7 x 107/unit and 3.2 - 5.2 x 106/unit respectively. A total of 26 units were analyzed for pH changes. Out of these units, 10 each were PRP-PC and BC-PC and 6 units were apheresis-PC. Their mean pH was 6.7±0.26 (mean±SD) and ranged from 6.5 - 7.0 and no difference was observed among all three types of platelet concentrate. Conclusion: PRP-PC and BC-PC units were comparable in terms of swirling, platelet count per unit and pH. As expected, we found WBC contamination to be less in BC-PC than PRP-PC units. Variation in volume was more in BC-PC than PRP-PC units and this suggests that further standardization is required for preparation of BC-PC. As compared to the above two platelet concentrates, all the units of apheresis-PC fulfilled the desired quality control criteria of volume. Apheresis-PC units showed better swirling and platelet count than PRP-PCs and BC-PCs. All the platelet concentrates units had pH well above the recommended norm.
Reference Key
ravindra2009asianquality Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Singh Ravindra;Marwaha Neelam;Malhotra Pankaj;Dash Sumitra
Journal journal of computational and applied research in mechanical engineering
Year 2009
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.