selective spectrophotometric and spectrofluorometric methods for the determination of amantadine hydrochloride in capsules and plasma via derivatization with 1,2-naphthoquinone-4-sulphonate

Clicks: 190
ID: 164219
2009
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #30 of 38 articles by views in Pesticide biochemistry and physiology

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
New selective and sensitive spectrophotometric and spectrofluorometric methods have been developed and validated for the determination of amantadine hydrochloride (AMD) in capsules and plasma. The methods were based on the condensation of AMD with 1,2-naphthoquinone-4-sulphonate (NQS) in an alkaline medium to form an orange-colored product. The spectrophotometric method involved the measurement of the colored product at 460  nm. The spectrofluorometric method involved the reduction of the product with potassium borohydride, and the subsequent measurement of the formed fluorescent reduced AMD-NQS product at 382  nm after excitation at 293  nm. The variables that affected the reaction were carefully studied and optimized. Under the optimum conditions, linear relationships with good correlation coefficients (0.9972–0.9974) and low LOD (1.39 and 0.013 𝜇g mL−1) were obtained in the ranges of 5–80 and 0.05–10  𝜇g mL−1 for the spectrophotometric and spectrofluorometric methods, respectively. The precisions of the methods were satisfactory; RSD ≤2.04%. Both methods were successfully applied to the determination of AMD in capsules. As its higher sensitivity, the spectrofluorometric method was applied to the determination of AMD in plasma; the recovery was 96.3–101.2±0.57–4.2%. The results obtained by the proposed methods were comparable with those obtained by the official method
Reference Key
mahmoud2009internationalselective Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Ashraf M. Mahmoud;Nasr Y. Khalil;Ibrahim A. Darwish;Tarek Aboul-Fadl
Journal Pesticide biochemistry and physiology
Year 2009
DOI
10.1155/2009/810104
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.