overview of cotinine cutoff values for smoking status classification

Clicks: 213
ID: 163571
2016
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #500 of 642 articles by views in archives of biochemistry and biophysics

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 642 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
While cotinine is commonly used as a biomarker to validate self-reported smoking status, the selection of an optimal cotinine cutoff value for distinguishing true smokers from true nonsmokers shows a lack of standardization among studies. This review describes how the cutoff values have been derived, and explains the issues involved in the generalization of a cutoff value. In this study, we conducted an English-language literature search in PubMed using the keywords “cotinine” and “cutoff” or “self-reported” and “smoking status” and “validation” for the years 1985–2014. We obtained 104 articles, 32 of which provided (1) sensitivity and specificity of a cutoff value and (2) determination methods for the given cutoff value. We found that the saliva cotinine cutoff value range of 10–25 ng/mL, serum and urine cotinine cutoff of 10–20 ng/mL and 50–200 ng/mL, respectively, have been commonly used to validate self-reported smoking status using a 2 × 2 table or a receiver operating characteristics (ROC) curve. We also found that recent large population-based studies in the U.S. and UK reported lower cutoff values for cotinine in serum (3 ng/mL) and saliva (12 ng/mL), compared to the traditionally accepted ones (15 and 14 ng/mg, respectively).
Reference Key
kim2016internationaloverview Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Sungroul Kim
Journal archives of biochemistry and biophysics
Year 2016
DOI
10.3390/ijerph13121236
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.