pattern visual evoked potential changes in diabetic patients without retinopathy

Clicks: 108
ID: 163252
2017
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #145 of 167 articles by views in chemical reviews

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 167 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Purpose. To assess the different check sizes of pattern visual evoked potential (PVEP) in diabetic patients without retinopathy according to HbA1c levels and diabetes duration. Methods. Fifty-eight eligible patients with type 2 diabetes mellitus and 26 age- and sex-matched healthy controls were included in the study. Only the right eye of each patient was analyzed. All of the patients underwent a comprehensive ophthalmic examination, and the PVEPs were recorded. Results. There was a statistically significant difference in P100 latency in 1-degree check size and in N135 latency in 2-degree check size between controls and patient groups which have different HbA1c levels. There were statistically significant, positive, and weak correlations with diabetes duration and P100 latency in 7-minute and 15-minute check sizes and N135 latency in 15-minute check size. Conclusions. It was showed that there were prolongations in P100 latency only in 1-degree check size and in N135 only in 2-degree check size in diabetic patients without retinopathy. There was statistically significant correlation between diabetes duration and P100 and N135 latencies in different check sizes.
Reference Key
balta2017journalpattern Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Ozgur Balta;Gulten Sungur;Mehmet Yakin;Nurten Unlu;Oyku Bezen Balta;Firdevs Ornek
Journal chemical reviews
Year 2017
DOI
10.1155/2017/8597629
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.