toward automatic cardiomyocyte clustering and counting through hesitant fuzzy sets
Clicks: 189
ID: 162560
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
189 views
22 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #20 of 27 articles by views in cancer immunology, immunotherapy : cii
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
The isolation and observation of cardiomyocytes serve as the fundamental approach to cardiovascular research. The state-of-the-practice for the isolation and observation relies on manual operation of the entire culture process. Such a manual approach not only incurs high human errors, but also takes a long period of time. This paper proposes a new computer-aided paradigm to automatically, accurately, and efficiently perform the clustering and counting of cardiomyocytes, one of the key procedures for evaluating the success rate of cardiomyocytes isolation and the quality of culture medium. The key challenge of the proposed method lies in the unique, rod-like shape of cardiomyocytes, which has been hardly addressed in literature. Our proposed method employs a novel algorithm inspired by hesitant fuzzy sets and integrates an efficient implementation into the whole process of analyzing cardiomyocytes. The system, along with the data extracted from adult rats’ cardiomyocytes, has been experimentally evaluated with Matlab, showing promising results. The false accept rate (FAR) and the false reject rate (FRR) are as low as 1.46% and 1.97%, respectively. The accuracy rate is up to 98.7%—20% higher than the manual approach—and the processing time is reduced from tens of seconds to 3−5 s—an order of magnitude performance improvement.
| Reference Key |
wang2019appliedtoward
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Jiayao Wang;Olamide Timothy Tawose;Linhua Jiang;Dongfang Zhao |
| Journal | cancer immunology, immunotherapy : cii |
| Year | 2019 |
| DOI |
10.3390/app9142875
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.