ms/ms studies for the selective detection of isomeric biogenic vocs using a townsend discharge triple quadrupole tandem ms and a ptr-linear ion trap ms

Clicks: 257
ID: 162521
2009
Free PDF
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Star

Ranked #55 of 183 articles by views in bioorganic & medicinal chemistry

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
We performed MS/MS investigations of biogenic volatile organic compounds (BVOC) using a triple quadrupole tandem mass spectrometer (QqQ-MS) equipped with a Townsend Discharge ion source and a Proton Transfer Reaction Linear Ion Trap (PTR-LIT) mass spectrometer. Both instruments use H<sub>2</sub>O chemical ionization to produce protonated molecules. Here we report a study of the application of these instruments to determine methyl vinyl ketone (MVK) and methacrolein (MACR) and a series of monoterpenes (α-pinene, β-pinene, 3-carene, limonene, myrcene, ocimene) and sesquiterpenes (humulene and farnesene). Both instruments achieved sub-ppb detection limits in the single MS mode and in the MS/MS mode for differentiating MVK and MACR. Collision induced dissociation (CID) of protonated monoterpenes and sesquiterpenes was studied under the relatively high-energy, single-to-few collision conditions of the QqQ-MS instrument and under the low-energy, multiple collision conditions of the PTR-LIT. Differences and similarities in the breakdown curves obtained are discussed. In addition, we performed MS<sup>4</sup> of protonated limonene to illustrate the analytical power of the PTR-LIT. In spite of the progress we have made, the selective on-line mass-spectrometric detection of individual monoterpenes or sesquiterpenes in complex mixtures currently does not yet seem to be possible.
Reference Key
mller2009atmosphericms/ms Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors
Journal bioorganic & medicinal chemistry
Year 2009
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.