extending the satellite data record of tropospheric ozone profiles from aura-tes to metop-iasi: characterisation of optimal estimation retrievals
Clicks: 200
ID: 162213
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
200 views
24 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #61 of 183 articles by views in bioorganic & medicinal chemistry
Most read
Least read
Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 183 in total.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
We apply the Tropospheric Emission Spectrometer (TES) ozone retrieval
algorithm to Infrared Atmospheric Sounding Instrument (IASI) radiances and
characterise the uncertainties and information content of the retrieved ozone
profiles. This study focuses on mid-latitudes for the year 2008. We validate
our results by comparing the IASI ozone profiles to ozone sondes. In the
sonde comparisons, we find a negative bias (1–10%) in the IASI profiles
in the lower to mid-troposphere and a positive bias (up to 14%) in the upper
troposphere/lower stratosphere
(UTLS) region. For the described cases, the degrees of freedom for signal are
on average 3.2, 0.3, 0.8, and 0.9 for the columns 0 km – top of atmosphere,
(0–6), (0–11), and (8–16) km, respectively. We find that our biases with
respect to sondes and our degrees of freedom for signal for ozone are
comparable to previously published results from other IASI ozone algorithms.
In addition to evaluating biases, we validate the retrieval errors by
comparing predicted errors to the sample covariance matrix of the IASI
observations themselves. For the predicted versus empirical error
comparison, we find that these errors are consistent and that the measurement
noise and the interference of temperature and water vapour on the retrieval
together mostly explain the empirically derived random errors. In general,
the precision of the IASI ozone profiles is better than 20%.
| Reference Key |
oetjen2014atmosphericextending
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;H. Oetjen;V. H. Payne;S. S. Kulawik;A. Eldering;J. Worden;D. P. Edwards;G. L. Francis;H. M. Worden;C. Clerbaux;J. Hadji-Lazaro;D. Hurtmans |
| Journal | bioorganic & medicinal chemistry |
| Year | 2014 |
| DOI |
10.5194/amt-7-4223-2014
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.