spectrophotometric study of the charge transfer complexation of tranexamic acid with 7,7,8,8-tetracyanoquinodimethane
Clicks: 335
ID: 161596
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
335 views
42 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #7 of 62 articles by views in Experimental physiology
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
A simple, sensitive and accurate spectrophotometric method for the determination of tranexamic acid (TXA) has been developed. The method was based on the charge transfer reaction between TXA as n-electron donor and 7,7,8,8-tetracyanoquinodimethane (TCNQ) as π-acceptor resulting in highly coloured stable complex, which showed maximum absorption band at wavelength of 419 nm. The formation of such complex was also confirmed by infrared measurement. The stoichiometry of the complex was found to be 1:1 between donor and acceptor as determined by Job’s continuous variation method and straight line method. The thermodynamic parameters were calculated as association constant KCT of 5109 mol−1 and Gibbs free energy ΔG° of 22.22 kJ mol−1. Different variables affecting the CT reaction were carefully studied and optimized. At the optimum reaction conditions, Beer’s law was obeyed in a concentration range of 1-18 µg mL−1 of TXA using TCNQ reagent and the limit of detection was 0.2 µg mL−1. Different analytical parameters, namely molar absorptivity (ε), relative standard deviation, correlation coefficient, limit of detection, and Sandell sensitivity, were calculated. The developed method could be applied successfully for the determination of TXA in its pharmaceutical dosage forms with a good precision and accuracy compared to the official method. DOI: http://dx.doi.org/10.4314/bcse.v28i2.3
| Reference Key |
sheng-yun2014bulletinspectrophotometric
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;L. Sheng-Yun;H. Yu-Cui |
| Journal | Experimental physiology |
| Year | 2014 |
| DOI |
10.4314/bcse.v28i2.3
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org