Percutaneous retrieval of an embolized gunshot bullet from right ventricle: a case report and review of literature.

Clicks: 291
ID: 15893
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Popular

Ranked #8 of 11 articles by views in european heart journal case reports

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Gunshots embolizing to the heart is a rare occurrence. We report a case of percutaneous retrieval of a gunshot bullet from the right ventricle (RV) cavity of a 40-year-old lady. To the best of our knowledge, this is the first case to be reported with a right supraclavicular inlet of the bullet and successful percutaneous retrieval using a snare from the RV cavity.A 40-year-old female patient was referred to our cardiac centre from a general hospital with a gunshot injury 8 days prior. On arrival, she was haemodynamically stable, there was an inlet wound at the right supraclavicular area. Transthoracic echocardiography revealed the bullet in the RV cavity. Under conscious sedation, right femoral vein access succeeded to retrieve the shot from the RV to the groin. The bullet slipped out and resnared from the right internal iliac vein and came out safely from the right femoral vein through the 24-Fr sheath. The vein was closed using a figure of 8 suture. The patient discharged home after 2 days.Bullet emboli to the heart are rare, endovascular retrieval of a bullet from the right ventricular cavity is feasible and relatively safe; however, more research is required. Echocardiography during the procedure is strongly recommended to early detect any complications. Accurate use of available tools such as X-ray, echocardiography, computed tomography, and fluoroscopy is a must for precise diagnosis.
Reference Key
naeim2019percutaneouseuropean Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Naeim, Hesham Abdo;Abuelatta, Reda;Sandogji, Hasan;ElRowiny, Ramy;
Journal european heart journal case reports
Year 2019
DOI
ytz059
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.