A ratiometric multicolor fluorescence biosensor for visual detection of alkaline phosphatase activity via a smartphone.
Clicks: 316
ID: 15846
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
75.1
/100
316 views
261 readers
Trending
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #29 of 85 articles by views in Biosensors & bioelectronics
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Herein we designed a selective and smartphone-based strategy for visual detection of alkaline phosphatase (ALP) by utilizing the property of amino-functionalized copper (II)-based metal-organic frameworks (NH-Cu-MOFs) with oxidase mimic property and fluorescence property. Surprisingly, the oxidase mimic property of NH-Cu-MOFs can work well at a high pH value 8.0. Thus, a cascade reaction between ALP and NH-Cu-MOFs was realized for the construction of a ratiometric multicolor sensing platform through the controllable catalytic activity of NH-Cu-MOFs by pyrophosphate (PPi) and ALP. The catalytic activity of NH-Cu-MOFs was greatly inhibited because of the binding ability of Cu with PPi. When the ALP was added, the catalytic activity of NH-Cu-MOFs was restored and then further catalyzed the o-phenylenediamine to form the 2, 3-diaminophenazine due to the hydrolysis function of ALP towards PPi into orthophosphates. RGB analysis of the fluorescent sample images was adopted for ALP quantitative analysis. Besides, a hydrogel test kit and mobile app for ALP detection were designed as conceptual products for point-of-care. The LODs of the fluorescence sensing platform was 0.078 mU mL and 0.35 mU mL by solution analysis and hydrogel test kit analysis, respectively. This fluorescent visual method was applied to ALP detection in serum samples with satisfying results, which opened a promising horizon for the diagnosis of other biomarkers in clinical serum samples based on ALP-mediated enzyme-linked immunosorbent assay for the development of biomedicine and clinical diagnosis.
| Reference Key |
hou2019abiosensors
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | Hou, Li;Qin, Yuxin;Li, Jinying;Qin, Siyuan;Huang, Yuanlin;Lin, Tianran;Guo, Liangqia;Ye, Fanggui;Zhao, Shulin; |
| Journal | Biosensors & bioelectronics |
| Year | 2019 |
| DOI |
S0956-5663(19)30684-0
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.