histogram analysis parameters apparent diffusion coefficient for distinguishing high and low-grade meningiomas: a multicenter study

Clicks: 137
ID: 158452
2018
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #39 of 52 articles by views in advances in acoustics and vibration

Most read Least read

Bar heights use a square-root scale.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Low grade meningiomas have better prognosis than high grade meningiomas. The aim of this study was to measure apparent diffusion coefficient (ADC) histogram analysis parameters in different meningiomas in a large multicenter sample and to analyze the possibility of several parameters for predicting tumor grade and proliferation potential. Overall, 148 meningiomas from 7 institutions were evaluated in this retrospective study. Grade 1 lesions were diagnosed in 101 (68.2%) cases, grade 2 in 41 (27.7%) patients, and grade 3 in 6 (4.1%) patients. All tumors were investigated by MRI (1.5 T scanner) by using diffusion weighted imaging (b values of 0 and 1000 s/mm2). For every lesion, the following parameters were calculated: mean ADC, maximum ADC, minimum ADC, median ADC, mode ADC, ADC percentiles P10, P25, P75, P90, kurtosis, skewness, and entropy. The comparison of ADC values was performed by Mann–Whitney-U test. Correlation between different ADC parameters and KI 67 was calculated by Spearman's rank correlation coefficient. Grade 2/3 meningiomas showed statistically significant lower ADC histogram analysis parameters in comparison to grade 1 tumors, especially ADC median. A threshold value of 0.82 for ADC median to predict tumor grade was estimated (sensitivity = 82.2%, specificity = 63.8%, accuracy = 76.4%, positive and negative predictive values were 83% and 62.5%, respectively).All ADC parameters except maximum ADC showed weak significant correlations with KI 67, especially ADC P25 (P = −.340, P = .0001).
Reference Key
surov2018translationalhistogram Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Alexey Surov;Daniel T Ginat;Tchoyoson Lim;Teresa Cabada;Ozdil Baskan;Stefan Schob;Hans Jonas Meyer;Georg Alexander Gihr;Diana Horvath-Rizea;Gordian Hamerla;Karl Titus Hoffmann;Andreas Wienke
Journal advances in acoustics and vibration
Year 2018
DOI
DOI not found
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.