the mechanism of “killer turn” causing residual laxity after transtibial posterior cruciate ligament reconstruction

Clicks: 201
ID: 157949
2016
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
Background: The residual laxity after transtibial posterior cruciate ligament (PCL) reconstruction has been reported by several authors. The sharp angle where the graft exits the tibial tunnel, which is known as “killer turn”, is believed to be the main reason. The purpose of this study was to reveal the mechanism of “killer turn” and its effect on both graft and tunnel inlet. Methods: A total of 60 New Zealand white rabbits were included. All transtibial PCL reconstructions were performed in vitro using Achilles tendon autograft. The cyclic loading tests were conducted when reconstructed knees were subjected to 1500 cycles of tensile force of 50 N with the angle of pull at 45° to the tibial plateau. The tunnel inlet enlargement, graft elongation, stiffness, graft displacement, load to failure, and failure site were all recorded and analysed. Results: Fifty-eight New Zealand white rabbits were available for biomechanical evaluation. The subjects had significant graft elongation and tunnel enlargement. The graft displacement increased by a mean of 0.92±0.36 mm (16.70%). At the 1500th cycle, the grafts were significantly elongated by 5.59±4.98%, and the tunnel inlet diameter was also significantly enlarged by 12.08±4.31%. There was a linear correlation between total graft displacement and the two variables (R2=0.402, F=18.515, p<0.001). The coefficient for tunnel inlet enlargement was 0.419 (p=0.006), and for graft elongation was 0.583 (p=0.002). At the load-to-failure test, the failure load was 81.19±20.13 N. Of the 58 grafts, 31 (53.45%) failed at the “killer turn”, 13 (22.41%) for the para-tunnel fracture, seven (12.07%) for the graft pull-out, and the remaining seven (12.07%) for the rupture at the mounting site. Conclusion: The mechanism of “killer turn” compromising posterior stability was that the repetitive friction between graft and tunnel inlet not only attenuated the graft, but also enlarged the tunnel inlet, leading to the displacement of the graft.
Reference Key
li2016asia-pacificthe Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Yue Li;Jin Zhang;Guanyang Song;Xu Li;Hua Feng
Journal zhongguo zhongyao zazhi
Year 2016
DOI
10.1016/j.asmart.2015.12.001
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.