enhancing the detection of bold signal in fmri by reducing the partial volume effect

Clicks: 328
ID: 157143
2014
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This article has not been analysed, so there is no overall score — reader engagement is measured and shown alongside.
AI Quality Assessment
Not analyzed
Readership in this journal
Steady

Ranked #7 of 191 articles by views in advanced functional materials

Most read Least read

Bar heights use a square-root scale. Only the 120 most-read articles are drawn; the journal has 191 in total.

Mint this article as an NFT
Not yet minted

Create a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.

5 SUSD one-off · no wallet required
Abstract
Purpose. To investigate the advantages of reducing the partial volume effect (PVE) to enhance the detection of the BOLD signal in fMRI. Methods. A linear phase term was added in k-space to obtain half-voxel shifting of 64 × 64 T2*-weighted echo-planar images. Three sets of image data shifted in the x, y, and diagonal direction, respectively, are combined with the original 64 × 64 data to form the 128 × 128 voxel-shifted interpolated data. Results. A simulation of a synthetic fMRI dataset shows that the voxel-shifted interpolation (VSI) can increase the t-score up to 50% in single-voxel activations. An fMRI study (n=7) demonstrates that 20.4% of the interpolated voxels have higher t-scores than their nearest neighboring voxels in the original maps. The average increase of the t-score in these interpolated voxels is 13.3%. Conclusion. VSI yields increased sensitivity in detecting voxel-size BOLD activations, improved spatial accuracy of activated regions, and improved detection of the peak BOLD signal of an activated region. VSI can potentially be used as an alternative to the high-resolution fMRI studies in which reduction in SNR and increase in imaging time become prohibitive.
Reference Key
du2014computationalenhancing Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;Yiping P. Du;Renxin Chu;Jason R. Tregellas