performing calibration of transmittance by single rgb-led within the visible spectrum
Clicks: 203
ID: 155378
2020
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Emerging Content
30.0
/100
203 views
51 readers
AI Quality Assessment
Not analyzed
Readership in this journal
EmergingRanked #39 of 63 articles by views in ekonomiczne problemy usług
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Spectrophotometry has proven to be an effective non-invasive technique for the characterization of the pollution load of sewer systems, enabling compliance with new environmental protection regulations. This type of equipment has costs and an energy consumption which make it difficult to place it inside a sewer network for real-time and massive monitoring. These shortcomings are mainly due to the use of incandescent lamps to generate the working spectrum as they often require the use of optical elements, such as diffraction gratings, to work. The search for viable alternatives to incandescent lamps is key to the development of portable equipment that is cheaper and with a lower consumption that can be used in different points of the sewer network. This research work achieved the following results in terms of the measured samples: First, the development a calibration procedure that enables the use of RGB-LED technology as a viable alternative to incandescent lamps, within the range of 510 to 645 nm, with high accuracy. Secondly, demonstration of a simple method to model the transmittance value of a specific wavelength without the need for optical elements, achieving a cost-effective equipment. Thirdly, it provides a simple method to obtain the transmittance based on the combination of RGB colors. Finally its viability is demonstrated for the spectral analysis of wastewater.
| Reference Key |
carreres-prieto2020sensorsperforming
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Daniel Carreres-Prieto;Juan T. García;Fernando Cerdán-Cartagena;Juan Suardiaz-Muro |
| Journal | ekonomiczne problemy usług |
| Year | 2020 |
| DOI |
10.3390/s20123492
|
| URL | |
| Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.