the validity of central venous to arterial carbon dioxide difference to predict adequate fluid management during living donor liver transplantation. a prospective observational study
Clicks: 274
ID: 155373
2019
Article Quality & Performance Metrics
Overall Quality
Not rated
Combines reader engagement with the AI quality analysis. This
article has not been analysed, so there is no overall score —
reader engagement is measured and shown alongside.
Reader Engagement
Steady Performance
30.0
/100
274 views
24 readers
AI Quality Assessment
Not analyzed
Readership in this journal
SteadyRanked #4 of 8 articles by views in american journal of emergency medicine
Most read
Least read
Bar heights use a square-root scale.
Mint this article as an NFT
Not yet mintedCreate a permanent, verifiable on-chain record of this article on the Scimatic Network. The NFT is held in your Journament account, and you can withdraw it to your own wallet at any time.
5
SUSD
one-off · no wallet required
Abstract
Abstract Background To assess the validity of central and pulmonary veno-arterial CO2 gradients to predict fluid responsiveness and to guide fluid management during liver transplantation. Methods In adult recipients (ASA III to IV) scheduled for liver transplantation, intraoperative fluid management was guided by pulse pressure variations (PPV). PPV of ≥15% (Fluid Responding Status-FRS) indicated fluid resuscitation with 250 ml albumin 5% boluses repeated as required to restore PPV to < 15% (Fluid non-Responding Status-FnRS). Simultaneous blood samples from central venous and pulmonary artery catheters (PAC) were sent to calculate central venous to arterial CO2 gap [C(v-a) CO2 gap] and pulmonary venous to arterial CO2 gap [Pulm(p-a) CO2 gap]. CO and lactate were also measured. Results Sixty seven data points were recorded (20 FRS and 47 FnRS). The discriminative ability of central and pulmonary CO2 gaps between the two states (FRS and FnRS) was poor with AUC of ROC of 0.698 and 0.570 respectively. Central CO2 gap was significantly higher in FRS than FnRS (P = 0.016), with no difference in the pulmonary CO2 gap between both states. The central and Pulmonary CO2 gaps are weakly correlated to PPV [r = 0.291, (P = 0.017) and r = 0.367, (P = 0.002) respectively]. There was no correlation between both CO2 gaps and both CO and lactate. Conclusion Central and the Pulmonary CO2 gaps cannot be used as valid tools to predict fluid responsiveness or to guide fluid management during liver transplantation. CO2 gaps also do not correlate well with the changes in PPV or CO. Trial registration Clinicaltrials.gov Identifier: NCT03123172. Registered on 31-march-2017.
Abstract Quality Issue:
This abstract appears to be incomplete or contains metadata (66 words).
Try re-searching for a better abstract.
| Reference Key |
elayashy2019bmcthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
|---|---|
| Authors | ;Mohamed ELAyashy;Hisham Hosny;Amr Hussein;Ahmed AbdelAal Ahmed Mahmoud;Ahmed Mukhtar;Amira El-Khateeb;Mohamed Wagih;Fawzia AboulFetouh;Amr Abdelaal;Hany Said;Mostafa Abdo |
| Journal | american journal of emergency medicine |
| Year | 2019 |
| DOI |
10.1186/s12871-019-0776-9
|
| URL | |
| Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.